Skip navigation

Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12128/9332
Title: Automatic method for the dermatological diagnosis of selected hand skin features in hyperspectral imaging
Authors: Koprowski, Robert
Wilczyński, S.
Wróbel, Zygmunt
Kasperczyk, S.
Błońska-Fajfrowska, B.
Keywords: Hyperspectral imaging; Image processing; Measurement automation; Segmentation
Issue Date: 2014
Citation: BioMedical Engineering, Vol. 13, iss. 1 (2014), art. no. 47
Abstract: Introduction: Hyperspectral imaging has been used in dermatology for many years. The enrichment of hyperspectral imaging with image analysis broadens considerably the possibility of reproducible, quantitative evaluation of, for example, melanin and haemoglobin at any location in the patient's skin. The dedicated image analysis method proposed by the authors enables to automatically perform this type of measurement. Material and method: As part of the study, an algorithm for the analysis of hyperspectral images of healthy human skin acquired with the use of the Specim camera was proposed. Images were collected from the dorsal side of the hand. The frequency λ of the data obtained ranged from 397 to 1030 nm. A total of 4'000 2D images were obtained for 5 hyperspectral images. The method proposed in the paper uses dedicated image analysis based on human anthropometric data, mathematical morphology, median filtration, normalization and others. The algorithm was implemented in Matlab and C programs and is used in practice. Results: The algorithm of image analysis and processing proposed by the authors enables segmentation of any region of the hand (fingers, wrist) in a reproducible manner. In addition, the method allows to quantify the frequency content in different regions of interest which are determined automatically. Owing to this, it is possible to perform analyses for melanin in the frequency range λE∈(450,600) nm and for haemoglobin in the range λH∈(397,500) nm extending into the ultraviolet for the type of camera used. In these ranges, there are 189 images for melanin and 126 images for haemoglobin. For six areas of the left and right sides of the little finger (digitus minimus manus), the mean values of melanin and haemoglobin content were 17% and 15% respectively compared to the pattern. Conclusions: The obtained results confirmed the usefulness of the proposed new method of image analysis and processing in dermatology of the hand as it enables reproducible, quantitative assessment of any fragment of this body part. Each image in a sequence was analysed in this way in no more than 100 ms using Intel Core i5 CPU M460 @2.5 GHz 4 GB RAM.
URI: http://hdl.handle.net/20.500.12128/9332
DOI: 10.1186/1475-925X-13-47
ISSN: 1475-925X
Appears in Collections:Artykuły (WNŚiT)

Files in This Item:
File Description SizeFormat 
Koprowski_Automatic_method_for_the_dermatological.pdf3,18 MBAdobe PDFView/Open
Show full item record


Uznanie Autorstwa 3.0 Polska Creative Commons License Creative Commons