Skip navigation

Zastosuj identyfikator do podlinkowania lub zacytowania tej pozycji: http://hdl.handle.net/20.500.12128/10679
Pełny rekord metadanych
DC poleWartośćJęzyk
dc.contributor.authorBaic, Błażej-
dc.contributor.authorKozłowska, Beata-
dc.contributor.authorKwiatkowski, Robert-
dc.contributor.authorDybek, Marcin-
dc.date.accessioned2019-08-29T09:50:38Z-
dc.date.available2019-08-29T09:50:38Z-
dc.date.issued2019-
dc.identifier.citationNukleonika, Vol. 64, iss. 3 (2019), s. 77-86pl_PL
dc.identifier.issn0029-5922E-
dc.identifier.urihttp://hdl.handle.net/20.500.12128/10679-
dc.description.abstractPhoton beams with wide energy ranges from 4 MV to 25 MV are commonly used in radiotherapy nowadays. In recent years, there has been a strong interest in a certain modifi cation of a radiotherapeutic apparatus by the application of the so-called fl attening fi lter-free (FFF) beam. Several advantages of FFF beams over standard fl attening fi lter (FF) beams are noticed, and this technical solution has aroused great interest among radiotherapeutic facilities. The goal of the present study is to investigate the differences between the conventional FF and unfl attened FFF 6-MV and 10-MV photon beams in some basic dosimetric parameters and their infl uence on the whole radiotherapeutic treatment. The data provided here include the detailed characteristics as follows: percent depth dose (PDD), beam profi le, edge of a half-profi le, total scatter correction factor (TSCF) and head scatter correction factor (HSCF) for FF and FFF 6-MV and 10-MV photon beams from the Elekta Versa HD accelerator in the Katowice Oncology Center in Poland.pl_PL
dc.language.isoenpl_PL
dc.rightsUznanie autorstwa-Użycie niekomercyjne-Bez utworów zależnych 3.0 Polska*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/*
dc.subjectclinical application of FFF beamspl_PL
dc.subjectdosimetric parameterspl_PL
dc.subjectunfl attened photon beamspl_PL
dc.titleClinical advantages of using unfl attened 6-MV and 10-MV photon beams generated by the medical accelerator Elekta Versa HD based on their dosimetric parameters in comparison to conventional beamspl_PL
dc.typeinfo:eu-repo/semantics/articlepl_PL
dc.relation.journalNukleonikapl_PL
dc.identifier.doi10.2478/nuka-2019-0010-
Pojawia się w kolekcji:Artykuły (WNŚiT)

Pliki tej pozycji:
Plik Opis RozmiarFormat 
Baic_Clinical_advantages_of_using_unfl_attened.pdf959,05 kBAdobe PDFPrzejrzyj / Otwórz
Pokaż prosty rekord


Uznanie autorstwa - użycie niekomercyjne, bez utworów zależnych 3.0 Polska Creative Commons Creative Commons