Skip navigation

Zastosuj identyfikator do podlinkowania lub zacytowania tej pozycji: http://hdl.handle.net/20.500.12128/19709
Tytuł: Badanie metodą EPR wolnych rodników w polimerze UHMWPE stosowanym w biomedycznych węzłach tarcia
Tytuł równoległy: The EPR method investigation of free radicals in polymer UHMWPE applied in the biomedical knots of the friction
Autor: Czaja, Piotr
Cybo, Jerzy
Maszybrocka, Joanna
Barylski, Adrian
Michnikowski, Jacek
Słowa kluczowe: polyethylene UHMWPE; electron beam radiation; free radicals; EPR method
Data wydania: 2011
Źródło: Tribologia, Nr 5 (2011), s. 39-47
Abstrakt: In this paper, the results of EPR measuring of free radicals for two types of polyethylene of ultra high molecular weight: GUR 1020 and GUR 1050 are presented. Samples were irradiated by electron beam energy of 10 MeV and dose 26 kGy a number of times (i = 1, 2, 3, 4, or 6). With the increase of radiation, the amount of free radicals increases as well. In both cases of polyethylene GUR 1020 and GUR 1050, the effect of saturation at the maximum dose of radiation equal 156 kGy was not observed. This proves that both types of material show similar radiation resistance.
URI: http://hdl.handle.net/20.500.12128/19709
ISSN: 0208-7774
1732-422X
Pojawia się w kolekcji:Artykuły (WNŚiT)

Pliki tej pozycji:
Plik Opis RozmiarFormat 
Czaja_Badanie_metoda_EPR.pdf1,24 MBAdobe PDFPrzejrzyj / Otwórz
Pokaż pełny rekord


Uznanie autorstwa na tych samych warunkach 3.0 Polska Creative Commons Creative Commons