Skip navigation

Zastosuj identyfikator do podlinkowania lub zacytowania tej pozycji: http://hdl.handle.net/20.500.12128/230
Pełny rekord metadanych
DC poleWartośćJęzyk
dc.contributor.authorKoprowski, Robert-
dc.date.accessioned2017-11-11T07:45:22Z-
dc.date.available2017-11-11T07:45:22Z-
dc.date.issued2016-
dc.identifier.citationBioMedical Engineering OnLine, Vol. 15, iss. 1 (2016), art. no. 111pl_PL
dc.identifier.issn1475-925X-
dc.identifier.urihttp://hdl.handle.net/20.500.12128/230-
dc.description.abstractBackground: The paper presents an automatic method for analysis and processing of images from a camera operating in visible light. This analysis applies to images containing the human facial area (body) and enables to measure the blood pulse rate. Special attention was paid to the limitations of this measurement method taking into account the possibility of using consumer cameras in real conditions (different types of lighting, different camera resolution, camera movement). Methods: The proposed new method of image analysis and processing was associated with three stages: (1) image pre-processing-allowing for the image filtration and stabilization (object location tracking); (2) main image processing-allowing for segmentation of human skin areas, acquisition of brightness changes; (3) signal analysis-filtration, FFT (Fast Fourier Transformation) analysis, pulse calculation. Results and conclusions: The presented algorithm and method for measuring the pulse rate has the following advantages: (1) it allows for non-contact and non-invasive measurement; (2) it can be carried out using almost any camera, including webcams; (3) it enables to track the object on the stage, which allows for the measurement of the heart rate when the patient is moving; (4) for a minimum of 40,000 pixels, it provides a measurement error of less than ±2 beats per minute for p < 0.01 and sunlight, or a slightly larger error (±3 beats per minute) for artificial lighting; (5) analysis of a single image takes about 40 ms in Matlab Version 7.11.0.584 (R2010b) with Image Processing Toolbox Version 7.1 (R2010b).pl_PL
dc.language.isoenpl_PL
dc.rightsUznanie autorstwa 3.0 Polska*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/pl/*
dc.subjectBlood pulsationpl_PL
dc.subjectDynamic analysispl_PL
dc.subjectImage processingpl_PL
dc.subjectPulsepl_PL
dc.titleBlood pulsation measurement using cameras operating in visible light: limitationspl_PL
dc.typeinfo:eu-repo/semantics/articlepl_PL
dc.relation.journalBioMedical Engineering OnLinepl_PL
dc.identifier.doi10.1186/s12938-016-0232-8-
Pojawia się w kolekcji:Artykuły (WNŚiT)

Pliki tej pozycji:
Plik Opis RozmiarFormat 
Koprowski_Blood_pulsation_measurement_using_cameras_operating_in_visible_light.pdf2,98 MBAdobe PDFPrzejrzyj / Otwórz
Pokaż prosty rekord


Uznanie Autorstwa 3.0 Polska Creative Commons Creative Commons