Skip navigation

Zastosuj identyfikator do podlinkowania lub zacytowania tej pozycji: http://hdl.handle.net/20.500.12128/260
Pełny rekord metadanych
DC poleWartośćJęzyk
dc.contributor.authorKoprowski, Robert-
dc.contributor.authorWróbel, Zygmunt-
dc.contributor.authorNowińska, Anna-
dc.contributor.authorWylęgała, Edward-
dc.date.accessioned2017-11-11T19:06:46Z-
dc.date.available2017-11-11T19:06:46Z-
dc.date.issued2013-
dc.identifier.citationBioMedical Engineering OnLine, Vol. 12, iss. 1 (2013), art. no. 74pl_PL
dc.identifier.issn1475-925X-
dc.identifier.urihttp://hdl.handle.net/20.500.12128/260-
dc.description.abstractIntroduction: Pseudoexfoliation syndrome (PEX) is a systemic disease involving the accumulation of pathological material deposits in the tissues of the anterior segment of the eye. The problem of modern ophthalmology is a quantitative assessment of the severity of PEX in the diagnosis and evaluation of the treatment progress in patients.Material and method: For the purposes of this study, 52 images of the anterior segment of the eye with the resolution of M × N = 1280 × 960 pixels were obtained in jpg format using the slit lamp CSO 450-SL. The patients were aged 50-80 and were recruited from Poland. All patients who participated in the study provided written informed consent after explanation of the nature and possible consequences of the study. The image analysis method proposed by the authors contains the calculation of the direction field, setting a straight perpendicular line passing through each pixel of the edge of the pupil, the calculation of the intersection of straight lines in order to determine the central point of the pupil position, the detection of the contour of PEX and the outer border of the iris with the use of the polar coordinate system. All analyzed parameters were set automatically with one exception parameter chosen manually depending on the slit lamp type.Results: A fully automatic measurement of PEX was carried out with the proposed method. Quantitative results enable to perform reproducible tests independently of the research centre. Owing to the image analysis method proposed by the authors, it is possible to obtain results in no more than 1 second on the Intel Core 2 Quad CPU 2.50 GHz with a measurement error below 3%. Other known methods of image analysis and processing that are compared in this paper give results with a greater error (4-35%) which depends on the degree of magnification (×6, ×16, ×20) and are not fully automatic.Conclusions: The methods of image analysis and processing enable a quantitative, repeatable and automatic measurement of the severity and progress of PEX syndrome. They support medical diagnosis and automatic archiving of results.pl_PL
dc.language.isoenpl_PL
dc.rightsUznanie autorstwa 3.0 Polska*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/pl/*
dc.subjectAutomaticpl_PL
dc.subjectEyepl_PL
dc.subjectImage processingpl_PL
dc.subjectPEXpl_PL
dc.subjectPseudoexfoliationpl_PL
dc.titleQuantitative measurement of pseudoexfoliation in the anterior segment of the eye performed in visible lightpl_PL
dc.typeinfo:eu-repo/semantics/articlepl_PL
dc.relation.journalBioMedical Engineering OnLinepl_PL
dc.identifier.doi10.1186/1475-925X-12-74-
Pojawia się w kolekcji:Artykuły (WNŚiT)

Pliki tej pozycji:
Plik Opis RozmiarFormat 
Koprowski_Quantitative_measurement_of_pseudoexfoliation_in_the_anterior_segment_of_the_eye_performed_in_visible_light.pdf4,49 MBAdobe PDFPrzejrzyj / Otwórz
Pokaż prosty rekord


Uznanie Autorstwa 3.0 Polska Creative Commons Creative Commons