Skip navigation

Zastosuj identyfikator do podlinkowania lub zacytowania tej pozycji: http://hdl.handle.net/20.500.12128/5435
Pełny rekord metadanych
DC poleWartośćJęzyk
dc.contributor.authorMałota, Zbigniew-
dc.contributor.authorGłowacki, Jan-
dc.contributor.authorSadowski, Wojciech-
dc.contributor.authorKostur, Marcin-
dc.date.accessioned2018-07-19T06:44:06Z-
dc.date.available2018-07-19T06:44:06Z-
dc.date.issued2018-
dc.identifier.citationBMC Cardiovascular Disorders, Vol. 18, iss. 1 (2018), Art. no. 132pl_PL
dc.identifier.issn1471-2261-
dc.identifier.urihttp://hdl.handle.net/20.500.12128/5435-
dc.description.abstractBackground: The stenosis of the coronary arteries is usually caused by atherosclerosis. Hemodynamic significance of patient-specific coronary stenoses and the risk of its progression may be assessed by comparing the hemodynamic effects induced by flow disorders. The present study shows how stenosis degree and variable flow conditions in coronary artery affect the oscillating shear index, residence time index, pressure drop coefficient and fractional flow reserve. We assume that changes in the hemodynamic indices in relation to variable flow conditions and geometries evaluated using the computational fluid dynamics may be an additional factor for a non-invasive assessment of the coronary stenosis detected on multi-slice computed tomography. Methods: The local-parametrised models of basic shapes of the vessels, such as straight section, bend, and bifurcation as well as the global-patient-specific models of left coronary artery were used for numerical simulation of flow in virtually reconstructed stenotic vessels. Calculations were carried out for vessels both without stenosis, and vessels of 10 to 95% stenosis. The flow rate varied within the range of 20 to 1000 ml/min, and heart rate frequency within the range of 30 to 210 cycles/min. The computational fluid dynamics based on the finite elements method verified by the experimental measurements of the velocity profiles was used to analyse blood flow in the coronary arteries. Results: The results confirm our preliminary assumptions. There is significant variation in the coronary hemodynamic indices value caused by disturbed flow through stenosis in relation to variable flow conditions and geometry of vessels. Conclusion: Variations of selected hemodynamic indexes induced by change of flow rate, heart rate and vessel geometry, obtained during a non-invasive study, may assist in evaluating the risk of stenosis progression and in carrying out the assessment of the hemodynamic significance of coronary stenosis. However, for a more accurate assessment of the variability of indices and coronary stenosis severity both local (near the narrowing) and global (in side branches) studies should be used.pl_PL
dc.language.isoenpl_PL
dc.rightsUznanie autorstwa 3.0 Polska*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/pl/*
dc.subjectComputational fluid dynamicspl_PL
dc.subjectCoronary artery stenosispl_PL
dc.subjectHemodynamic indicespl_PL
dc.titleNumerical analysis of the impact of flow rate, heart rate, vessel geometry, and degree of stenosis on coronary hemodynamic indicespl_PL
dc.typeinfo:eu-repo/semantics/articlepl_PL
dc.identifier.doi10.1186/s12872-018-0865-6-
Pojawia się w kolekcji:Artykuły (WNŚiT)

Pliki tej pozycji:
Plik Opis RozmiarFormat 
Malota_Numerical_analysis_of_the_impact_of_flow_rate.pdf5,56 MBAdobe PDFPrzejrzyj / Otwórz
Pokaż prosty rekord


Uznanie Autorstwa 3.0 Polska Creative Commons Creative Commons