Skip navigation

Zastosuj identyfikator do podlinkowania lub zacytowania tej pozycji: http://hdl.handle.net/20.500.12128/12700
Pełny rekord metadanych
DC poleWartośćJęzyk
dc.contributor.authorFicek, Krzysztof-
dc.contributor.authorRajca, Jolanta-
dc.contributor.authorStolarz, Mateusz-
dc.contributor.authorStodolak-Zych, Ewa-
dc.contributor.authorWieczorek, Jarosław-
dc.contributor.authorMuzalewska, Małgorzata-
dc.contributor.authorWyleżoł, Marek-
dc.contributor.authorWróbel, Zygmunt-
dc.contributor.authorBinkowski, Marcin-
dc.contributor.authorBłażewicz, Stanisław-
dc.date.accessioned2020-02-19T12:48:16Z-
dc.date.available2020-02-19T12:48:16Z-
dc.date.issued2019-
dc.identifier.citationPolymers, Vol. 11 (2019), Art. No. 1961pl_PL
dc.identifier.issn2073-4360-
dc.identifier.urihttp://hdl.handle.net/20.500.12128/12700-
dc.description.abstractThe exact causes of failure of anterior cruciate ligament (ACL) reconstruction are still unknown. A key to successful ACL reconstruction is the prevention of bone tunnel enlargement (BTE). In this study, a new strategy to improve the outcome of ACL reconstruction was analyzed using a bioresorbable polylactide (PLA) stent as a catalyst for the healing process. The study included 24 sheep with 12 months of age. The animals were randomized to the PLA group (n = 16) and control group (n = 8), subjected to the ACL reconstruction with and without the implantation of the PLA tube, respectively. The sheep were sacrificed 6 or 12 weeks post-procedure, and their knee joints were evaluated by X-ray microcomputed tomography with a 50 m resolution. While the analysis of tibial and femoral tunnel diameters and volumes demonstrated the presence of BTE in both groups, the enlargement was less evident in the PLA group. Also, the microstructural parameters of the bone adjacent to the tunnels tended to be better in the PLA group. This suggested that the implantation of a bioresorbable PLA tube might facilitate osteointegration of the tendon graft after the ACL reconstruction. The beneficial e ects of the stent were likely associated with osteogenic and osteoconductive properties of polylactide.pl_PL
dc.language.isoenpl_PL
dc.rightsUznanie autorstwa 3.0 Polska*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/pl/*
dc.subjectanterior cruciate ligament reconstructionpl_PL
dc.subjectbone tunnel enlargementpl_PL
dc.subjectX-raymicrotomographypl_PL
dc.subjectpolylactidepl_PL
dc.titleBioresorbable Stent in Anterior Cruciate Ligament Reconstructionpl_PL
dc.typeinfo:eu-repo/semantics/articlepl_PL
dc.identifier.doi10.3390/polym11121961-
Pojawia się w kolekcji:Artykuły (WNŚiT)

Pliki tej pozycji:
Plik Opis RozmiarFormat 
Ficek_Bioresorbable_stent_in_anterior_cruciate.pdf2,35 MBAdobe PDFPrzejrzyj / Otwórz
Pokaż prosty rekord


Uznanie Autorstwa 3.0 Polska Creative Commons Creative Commons