Skip navigation

Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12128/6931
Title: Test of production of 198Au radioisotope by means of typical medical linear accelerators used in teleradiotherapy
Authors: Bzymek, Ewelina
Konefał, Adam
Orlef, Andrzej
Maniakowski, Zbigniew
Sokół, Maria
Keywords: teleradioterapia; radioizotopy; liniowe akceleratory medyczne
Issue Date: 2017
Citation: Acta Physica Polonica B, Vol. 48, no. 3 (2017), s. 671-674
Abstract: The test of production of the Au-198 radioisotope by means of Varian medical linear accelerators used in teleradiotherapy was carried out. The targets made of the natural gold (100% of the Au-197 isotope) were irradiated with high-energy therapeutic 20 MV X-ray beam. Au-198 was produced in the simple capture reaction Au-197(n, gamma) Au-198. The obtained specific activities in the saturation state are relatively low, not exceeding the value of 510.4 kBq/g, because only the high-energy part of the spectrum of 20 MV X-ray beam covers the energy range of the neutron production cross section. Low activity of the Au-198 radioisotope produced by medical linear accelerators makes this technique not suitable for a massive production of Au-198 for nuclear medicine, but the produced amount of Au-198 is sufficient for laboratory tests of new drugs for possible clinical applications.
URI: http://hdl.handle.net/20.500.12128/6931
ISSN: 0587-4254
Appears in Collections:Artykuły (WNŚiT)

Files in This Item:
File Description SizeFormat 
Bzymek_test_of_production.pdf930,46 kBAdobe PDFView/Open
Show full item record


Uznanie Autorstwa 3.0 Polska Creative Commons License Creative Commons